ne Two-Channel Amplifiers

 

Our 2-channel ne (Networked-Enabled) Series Amplifiers are designed to meet the specifications of the performance installation and constant voltage markets.

The ne800 delivers 400W per channel @ 4 Ohms and is available in 25V, 70V and 100V models. The ne1600 is rated at 800W per channel @ 4 Ohms and is available in 70V and 100V models. The largerest amp in this line, the ne2400, delivers 1,200W per channel into a 4 Ohm or 70V load; a separate 100V output model is rated at 1,200W.

All models include balanced analog inputs, bridge mono mode, selectable 80Hz hi-pass filter, input sensitivity switch, full Ethernet control using Protea™ ne Software, remote standby for power up, and DC remote level control using an Ashly WR-1 or equivalent. ne Amplifiers are a great value for any install.

ne800, ne1600 & ne2400 Features:

  • 10/100 Ethernet comes standard for remote control and monitoring
  • FIR Filter capabable (with DSP)
  • Optional, Protea DSP, AES3, CobraNet® and Dante®
  • DC voltage remote gain control
  • Switched-mode power supply, Class-D output
  • Stepped, calibrated input attenuators
  • Selectable input sensitivity 26dB, 32dB or 4V
  • Remote power stand-by
  • Disable all front panel controls via software
  • Temperature sensitive variable speed fan with side-to-front airflow
  • Selectable 80Hz HPF
  • 4-stage level meters
  • Output current and temp indicators
  • Safety/Compliance: CE, FCC, RoHS
  • Low-Z, 25V, 70V, 100V models
ne Models ne800 ne1600 ne2400
Continuous Average Power Output: Per Channel, Low Z Models, Stereo Mode, All Channels Driven
8 Ohms 225W 450W 700W
4 Ohms 400W 800W 1200W
Low Z Output: Bridge Mode, All Channels Driven
8 Ohms 800W 1600W 2400W
25V, 70V, 100V Distributed Output Models: 20Hz–20kHz 1% THD
25V (per channel) 400W
70V (per channel) 400W 800W
100V (per channel) 400W 800W 1200W
Line Current Draw: 120VAC Mains (divide in half for 230V)
Standby Mode 200mA 165mA 200mA
No Signal 475mA 500mA 475mA
Typical (1/8 power pink noise) 2.81A 4.95A 6.75A
Maximum (1/3 power pink noise) 4.93A 8.80A 12.6A
Thermal Dissipation: BTU/hr, All Channels Driven
Standby mode 40 40 40
Idle (no signal) 109 109 109
Typical (1/8 power pink noise) 287 447 682
Maximum (1/3 power pink noise) 297 466 717